Temperature field measurements between a Bunsen flame and flat a cold plate by using PLIF

Результат исследования: Научные публикации в периодических изданияхстатья по материалам конференциирецензирование

Аннотация

The present experimental work reports on the temperature measurements in a Bunsen flame, covered by a flat cooled plate from the top. The temperature field is measured based on the planar laser-induced fluorescence method for hydroxyl radical (OH) during the excitation of excitation Q1(8) line of the (1-0) band of the A2ς+-X2Π electronic system. Thermometry was based on the imaging of the ratio of the fluorescence intensity for the band (2-0) and bands (0-0), (1-1). The paper presents the obtained temperature fields for the distances between the plate and the burner of 1, 2 and 3 calibres. The paper also concludes that the used method can be implemented using a single-pulse laser illumination and is effective for the detection of cold zones.

Язык оригиналаанглийский
Номер статьи012014
ЖурналJournal of Physics: Conference Series
Том2233
Номер выпуска1
DOI
СостояниеОпубликовано - 25 апр 2022
Событие11th All-Russian Conference with International Participation on Fuel Combustion: Theory, Experiment, Applications, FCTEA 2021 - Novosibirsk, Российская Федерация
Продолжительность: 9 ноя 202112 ноя 2021