Аннотация
This paper describes the operation principles and design features of the device for single pulse X-raying of explosive and high-speed processes, developed on the basis of a Tesla transformer with lumped secondary capacitor bank. The circuit with the lumped capacitor bank allows transferring a greater amount of energy to the discharge circuit as compared with the Marks-surge generator for more effective operation with remote X-ray tubes connected by coaxial cables. The device equipped with multiple X-ray tubes provides simultaneous X-raying of extended or spaced objects, stereo imaging, or few-projection tomography.
Язык оригинала | английский |
---|---|
Номер статьи | 012069 |
Число страниц | 5 |
Журнал | Journal of Physics: Conference Series |
Том | 894 |
Номер выпуска | 1 |
DOI | |
Состояние | Опубликовано - 22 окт 2017 |