Nuclear-Polarized Hydrogen/Deuterium Molecular Source

Yu V. Shestakov, D. M. Nikolenko, I. A. Rachek, D. K. Toporkov, A. V. Yurchenko

Результат исследования: Научные публикации в периодических изданияхстатьярецензирование

1 Цитирования (Scopus)

Аннотация

The prototype of a nuclear-polarized hydrogen/deuterium molecular source based on the classical Stern-Gerlach design was tested at the Budker Institute of Nuclear Physics. Its major components are an annular nozzle cooled down to 6.5 K and two superconducting sextupole magnets. The measured flow of polarized hydrogen molecules was 3 x 10(12) mol/s at a total gas flow through the nozzle of 4 x10(-2) Torr L/s. The results obtained will be used to construct a more intense source of polarized molecules.

Язык оригиналаанглийский
Страницы (с-по)513-519
Число страниц7
ЖурналPhysics of Particles and Nuclei
Том50
Номер выпуска5
DOI
СостояниеОпубликовано - 1 сент. 2019

Fingerprint

Подробные сведения о темах исследования «Nuclear-Polarized Hydrogen/Deuterium Molecular Source». Вместе они формируют уникальный семантический отпечаток (fingerprint).

Цитировать