New detector and data processing procedure to measure velocity angular distribution function of magnetized relativistic electrons

A. V. Arzhannikov, M. A. Makarov, D. A. Samtsov, S. L. Sinitsky, V. D. Stepanov

Результат исследования: Научные публикации в периодических изданияхстатьярецензирование

Аннотация

Based on the regularities of the electron absorption in the ring collectors a new method for reconstructing the angular distribution function of the magnetized electrons has been worked out. To realize it the angular spread detector with a cylindrical channel of a variable cross-section was developed and applied in an experiment with a high-current electron beam. The results of the measurements with this detector have demonstrated the possibility to achieve an angular spread of 0.1 rad level in microsecond high-current beams generated in a magnetically insulated diode with an explosive-emission cathode at a voltage of ∼1 MV.