Аннотация

In this study, we present depth-dose profiles measured with a water phantom at the boron neutron-capture therapy (BNCT) facility at Budker Institute of Nuclear Physics (BINP). The presented results demonstrate that the proposed design of radiation detector with an optical fiber readout, which includes three different sensors (the first based on a plastic scintillator enriched with boron, the second based on a simple plastic scintillator, and the third having no scintillator at all), enables measurement of neutron flux, as well as estimations of the dose induced by gamma rays. The results of simulations with the GEANT4 package demonstrated good agreement with the experimental data and can be used for further system improvement.

Язык оригиналаанглийский
Номер статьиP10016
ЖурналJournal of Instrumentation
Том16
Номер выпуска10
DOI
СостояниеОпубликовано - окт 2021

Предметные области OECD FOS+WOS

  • 1.01 МАТЕМАТИКА
  • 1.03 ФИЗИЧЕСКИЕ НАУКИ И АСТРОНОМИЯ

Fingerprint

Подробные сведения о темах исследования «Evaluation of depth-dose profiles in a water phantom at the BNCT facility at BINP». Вместе они формируют уникальный семантический отпечаток (fingerprint).

Цитировать