Analysis of the Parameters of Pulse Signals by the Correlation Method Using the Example of High-Voltage Inflectors of the Damping Ring of a Vepp-5 Injection Complex

V. Balakin, D. Berkaev, F. Emanov, S. Vasilev, D. Bolkhovityanov

Результат исследования: Научные публикации в периодических изданияхстатья

Аннотация

After the VEPP-2000 and VEPP-4M colliders are switched to being supplied by beams from the VEPP-5 injection complex, the problem of ensuring the operation stability of the damping ring inflectors arises. Software on the basis of correlation analysis has been created to study the amplitude and delay deviations of the pulses of inflector generators. This allows the delay deviations of 1 ns for inflector signals that were digitized using ADC with a sampling frequency of 200 MHz to be observed. The dependence of the generator- delay deviation on the network voltage has been also discovered as a result of long-term observations.

Язык оригиналаанглийский
Страницы (с-по)891-893
Число страниц3
ЖурналPhysics of Particles and Nuclei Letters
Том15
Номер выпуска7
DOI
СостояниеОпубликовано - 1 дек 2018

Fingerprint Подробные сведения о темах исследования «Analysis of the Parameters of Pulse Signals by the Correlation Method Using the Example of High-Voltage Inflectors of the Damping Ring of a Vepp-5 Injection Complex». Вместе они формируют уникальный семантический отпечаток (fingerprint).