Abstract

Current status and last results of the Spherical Neutral Detector (SND) calorimeter upgrade are described. The main part of SND detector is a three-layer spherical NaI(Tl) electromagnetic calorimeter (EMC). The total thickness of NaI(Tl) in the calorimeter is 35 cm. The vacuum phototriodes (VPT) are used as photosensitive devices for the calorimeter counters. The quantum efficiency of VPT is about 15%, the average gain is 10, and the light collection efficiency is about 10%. New spectrometric channel of EMC was designed and implemented. It consists of a NaI(Tl) crystal, a vacuum phototriode, a charge-sensitive preamplifier a shaper and digitizing modules. The digitization is performed by 6 ADCs AD9228BCPZ-40 (4 channel, 12 bits, 40 MBPS) and the data go in serial form to the SoC Xilinx Zynq-7000. This SoC is basically a combination of FPGA programmable logic and ARM processor. The special algorithm for signal waveform processing was developed to determine time of flight and amplitude with high time (1 ns) and amplitude (250 keV) resolution. The algorithm is based on the invariability of the signal waveform. The waveform calibration procedures are developed and implemented. Successful data taking run was performed with upgraded EMC in 2019.

Original languageEnglish
Article numberC06011
Number of pages6
JournalJournal of Instrumentation
Volume15
Issue number6
DOIs
Publication statusPublished - 5 Jun 2020

Keywords

  • Calorimeter methods
  • Calorimeters

OECD FOS+WOS

  • 2.11 OTHER ENGINEERING AND TECHNOLOGIES

Fingerprint

Dive into the research topics of 'Upgrade of the SND electromagnetic calorimeter'. Together they form a unique fingerprint.