Test of microchannel plates in magnetic fields up to 4.5 T

A. Yu Barnyakov, M. Yu Barnyakov, V. G. Prisekin, S. V. Karpov, A. A. Katcin

Research output: Contribution to journalArticlepeer-review

17 Citations (Scopus)

Abstract

Detectors based on microchannel plates (MCP) can provide high time resolution and are able to operate in high magnetic field. An experimental setup based on a superconductive solenoid with 120 mm bore was created in BINP. The influence of magnetic field up to 4.5 T on the MCP photomultiplier parameters was studied. Several types of photodetectors produced in Novosibirsk were tested. Results of time resolution measurements, dependencies of gain and photon detection efficiency on magnetic field are presented. (C) 2016 Elsevier B.V. All rights reserved.

Original languageEnglish
Pages (from-to)588-590
Number of pages3
JournalNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Volume845
DOIs
Publication statusPublished - 11 Feb 2017

Keywords

  • Magnetic field
  • Microchannel plate
  • Photomultiplier
  • PMT
  • Time resolution
  • PHOTOTUBES

Fingerprint Dive into the research topics of 'Test of microchannel plates in magnetic fields up to 4.5 T'. Together they form a unique fingerprint.