Abstract

The excellent particle identification (PID) system is needed for the successful execution of the broad experimental program at future Super C-τ Factory (SCTF) in Novosibirsk. The main requirements for the PID system are the following: good π/K-separation in whole operational momentum range and good μ/π-separation in the momentum range from 0.4 up to 1.2 GeV/c. The RICH detector based on focusing aerogel (FARICH) could provide good π/K-separation from 0.4 GeV/c and μ/π-separation in the momentum range from 0.4 up to 1.5 GeV/c. The method FARICH is described, beam test results are presented and the status of multilayer aerogel production is given.

Original languageEnglish
Article numberC10014
Number of pages11
JournalJournal of Instrumentation
Volume15
Issue number10
DOIs
Publication statusPublished - Oct 2020

Keywords

  • Cherenkov detectors
  • Materials for solid-state detectors
  • Particle identification methods
  • Photon detectors for UV
  • visible and IR photons (solid-state)
  • PROTOTYPE
  • AEROGEL
  • RICH

Fingerprint Dive into the research topics of 'FARICH detector beam test results'. Together they form a unique fingerprint.

Cite this