Abstract

After the VEPP-2000 and VEPP-4M colliders are switched to being supplied by beams from the VEPP-5 injection complex, the problem of ensuring the operation stability of the damping ring inflectors arises. Software on the basis of correlation analysis has been created to study the amplitude and delay deviations of the pulses of inflector generators. This allows the delay deviations of 1 ns for inflector signals that were digitized using ADC with a sampling frequency of 200 MHz to be observed. The dependence of the generator- delay deviation on the network voltage has been also discovered as a result of long-term observations.