An experimental model of the evaporative cooling system of a single powerful LED

Research output: Contribution to journalArticle

Abstract

An experimental model of the evaporative cooling system of a single powerful LED with a natural circulation of the coolant capable of removing a heat flux density of more than 1 kW / cm2 is created. It is shown that on the finned surfaces the overheating relative to the saturation temperature in comparison with a smooth surface decreases up to three times for the heater with a diameter of 5 mm. There is up to two times increase in heat transfer coefficient on finned surfaces as compared to the smooth ones. For finned surfaces on the heater with a diameter of 1 mm the surface overheating relative to the saturation temperature decreases in four times. More than three times increase is observed for the heat transfer coefficient on finned surfaces as compared to the smooth ones.

Original languageEnglish
Article number0046
JournalEPJ Web of Conferences
Volume159
DOIs
Publication statusPublished - 25 Oct 2017

Fingerprint Dive into the research topics of 'An experimental model of the evaporative cooling system of a single powerful LED'. Together they form a unique fingerprint.